This page was exported from Valid Premium Exam [ http://premium.validexam.com ] Export date:Fri Sep 20 0:55:15 2024 / +0000 GMT ___________________________________________________ Title: (2022) PASS H12-425_V2.0-ENU Exam Free Practice Test with 100% Accurate Answers [Q130-Q154] --------------------------------------------------- (2022) PASS H12-425_V2.0-ENU Exam Free Practice Test with 100% Accurate Answers H12-425_V2.0-ENU dumps Free Test Engine Verified By It Certified Experts NO.130 What are the main reasons for the energy saving effect of closed cold/hot aisle? (Multiple choice)  Isolate the cold air, avoid the confusion of the hot air, and improve the utilization rate of the air  It can increase the supply air temperature of the air conditioner, thereby reducing the energy consumption of the air conditioner  The closed hot aisle can increase the return air temperature and improve the cooling efficiency  By increasing the supply air temperature, the amount of humidification is reduced, thereby reducing the power consumption of humidification NO.131 What kind of incoming and outgoing lines can be realized by the FusionModule2000 integrated power distribution cabinet?  Under the line and under the line  Up in and out on the line  Top-in and bottom-out lines  Down in and out on the line NO.132 What operations can be performed in the NetEco “Report Task” interface? (Multiple choice)  View Report Tasks  Create report task  Start the report task  Stop the report task NO.133 How many 12v batteries can the optional battery inspection instrument of UPS5000-A-400/500K support?  24  12  32  40 NO.134 UPS5000-E only needs to select ( ) to easily realize the N+X power supply system. The operation is simple and convenient. (Fill in the blank)  Parallel cable NO.135 In FusionModule1000B series solutions, when 2N power supply and distribution system is selected, can meet TIER4 wind power requirements.  True  False NO.136 Which of the following voltage systems does the UPS5000-E support? (Multiple choice)  380V  480V  415V  400v NO.137 Regarding the Fusionlodule2000 wiring, which of the following statements is wrong?  Cross-channel routing is through the control skylight  The wiring trough supports the separation of strong and weak electricity  The power distribution cabinet/integrated UPS cannot be placed at the head of the column  Cross-channel routing requires installation of cable ladders NO.138 The PDU8000 precision power distribution cabinet supports the monitoring of branch circuit phase current, active power, electric energy and branch circuit switch status.  True  False NO.139 The FusionModule800 does not need to be charged with refrigerant on site within 30m of the connecting pipe.  True  False NO.140 When the outdoor units of Huawei air-cooled air conditioners are installed horizontally, the distance between the two outdoor units is ≥ () MM.  400  800  1200  2000 NO.141 UPS5000-A supports the adjustable number of battery cells, which avoids the replacement of a whole group caused by a single battery failure, and solves the problem of difficult maintenance of traditional UPS batteries in the range of 30-40 cells.  True  False NO.142 How many temperature and humidity monitoring modules are required for each temperature control product?  1  2  3  4 NO.143 ATS (Automatic Transfer Switch) must overflow the manual operating handle in the case of automatic mode.  True  False NO.144 The temperature control laboratory has passed the GMPI certification.  True  False NO.145 The terminal power of the battery in the open circuit state is called ().  Rated voltage  Discharge voltage  Open-circuit voltage  Actual voltage NO.146 On the panel of the air-conditioning unit, in the group control topology diagram, the difference between this unit and other units is that there is a green frame.  TRUE  FALSE NO.147 Which of the following is a component of Huawei’s indirect evaporative cooling system? (Multiple Choice)  Indirect heat exchange system  Mechanical supplemental cooling system  Sprinkler System  Electronic control system NO.148 What is the maximum capacity of the power module of the UPS5000-E?  30kVA  20kVA  50kVA  40kVA NO.149 When the battery status of the UPS2000G is NA, it may be ().  The battery is not connected  Battery Low Voltage  The battery connection is normal  The battery N line is not connected NO.150 The PUE value of the data center is close to 1, indicating that the energy efficiency level is better.  TRUE  FALSE NO.151 If the customer has high requirements on the availability of the management system and requires that the normal use of the system is not affected by a single point of failure of the hardware, the NetEco management system can provide a high-availability solution of dual-system backup. In the dual-computer solution, what hardware resources are required by NetEco?  2 servers + 1 disk array + 1 switch  2 servers + 2 disk arrays + 3 switches  1 server + 1 t-disk array + 2 switches  None of the above is true NO.152 Which of the following are the accessories for UPS5000-A-400/500K? (Multiple choice)  Battery temperature sensor  Port battery inspection instrument  Dry contact expansion board  Upper air outlet assembly NO.153 Video can only be viewed on NETECO after the video camera has been configured on the IVS.  True  False NO.154 When a fire breaks out in the box and the fire extinguishing device releases the fire extinguishing agent into the protection area, ( ) will display the words “In The Vent, Do Not Enter”.  Fire alarm  Sound and light alarm  Deflation indicator light  Emergency Lights  Loading … Latest Huawei H12-425_V2.0-ENU Practice Test Questions: https://www.validexam.com/H12-425_V2.0-ENU-latest-dumps.html --------------------------------------------------- Images: https://premium.validexam.com/wp-content/plugins/watu/loading.gif https://premium.validexam.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2022-08-06 13:13:08 Post date GMT: 2022-08-06 13:13:08 Post modified date: 2022-08-06 13:13:08 Post modified date GMT: 2022-08-06 13:13:08