This page was exported from Valid Premium Exam [ http://premium.validexam.com ] Export date:Mon Feb 24 2:57:18 2025 / +0000 GMT ___________________________________________________ Title: Updated NS0-194 Dumps Questions Are Available [2022] For Passing Network Appliance Exam [Q15-Q38] --------------------------------------------------- Updated NS0-194 Dumps Questions Are Available [2022] For Passing Network Appliance Exam Free UPDATED Network Appliance NS0-194 Certification Exam Dumps is Online NO.15 Exhibit:Your customer has recently migrated from their FAS3140 system running Data ONTAP 7.3.7 to a FAS2552 system running Data ONTAP 8.2.3 7-Mode through the head upgrade process.They are no longer receiving the weekly AutoSupport notifications and want to know why. The exhibit shows the AutoSupport options from the nodes that have the same settings.In this scenario, which solution is correct?  There is no reason on the FAS2552 side why the customer should not receive the AutoSupport notifications. They should investigate their mail server to troubleshoot this issue.  In Data ONTAP 8.2, weekly AutoSupport notifications are no longer sent to the autosupport.to recipient, but only to autosupport.partner.to and to autosupport.support.to. The customer needs to add their e-mail address to one of these options.  In Data ONTAP 8.2, the protocol for AutoSupport is changed to HTTPS by default, so the customer must have an HTTPS destination for the AutoSupport data.  In Data ONTAP 8.2, weekly AutoSupport notifications are no longer sent to all recipients to reduce the mail load. The customer should add their e-mail address to the autosupport. partner. to option. NO.16 You want to use the supported method to upgrade the ONTAP version of a Cloud Volumes ONTAP instance from ONTAP 9.5 to ONTAP 9.6.In this scenario, which NetApp tool accomplishes this task?  Cloud Manager  Cloud Insights  Active IQ Unified Manager  ONTAP System Manager NO.17 Referring to the exhibit.Which two actions would you perform to address the system alternate-control-path (ACP) connectivity issue shown in the exhibit? (Choose two.)  Perform a takeover and giveback.  Turn options acp.enable off and then on.  Reseat the shelf modules.  Reseat the ACP cable. NO.18 Which three transport protocols are used to deliver AutoSupport data to NetApp? (Choose three.)  SSH  SMTP  HTTP  FTP  HTTPS NO.19 In the AFF A200 shown in the exhibit, which port is a CNA port?  |0|0|  e0c/0c  e0a  0a Explanation/Reference: https://docs.netapp.com/platstor/topic/com.netapp.doc.hw-2700-install-setup/GUID-FE4BD3C8-3DB4-438A-A5CE-FEEF74AE8BAF.htmlNO.20 You are migrating volumes from an older aggregate to a new aggregate using the vol move command. You notice that, after completion, access to these volumes is slower until a certain process finishes.Which process is causing the problem in this scenario?  active bitmap rearrangement  container block reclamation  deswizzling  snap create NO.21 A customer with a small FAS2240-4 Data ONTAP 7-Mode 8.1.1 installation is having aggregate capacity problems.When you requested the output of the aggr show_space command, the customer noticed from the output that A-SIS is using a lot of capacity and the customer is concerned.In this scenario, what do you tell the customer?  The A-SIS field from the command shows the amount of data that is actually on the aggregate before deduplication saved space on the aggregate.  The A-SIS field from the command shows how much capacity is used on the aggregate for the deduplication fingerprint database.  The A-SIS field from the command shows the number of duplicate blocks present in the aggregate that could be removed when deduplication is enabled on that aggregate.  The A-SIS field from the command shows how much data was saved by deduplication on the aggregate. NO.22 A customer will need to perform an upgrade from 9.0 to 9.4.Which feature of ONTAP enables nondisruptive hardware maintenance for this upgrade?  aggregate relocation  FlexVol  FlexGroup  RAID-TEC NO.23 A customer has a cluster running ONTAP where AutoSupport notifications have worked in the past but have recently stopped working. In this scenario, what are two steps to begin troubleshooting the problem? (Choose two.)  Review the AutoSupport history on the controller pair.  Use support entitlement on the NetApp Support site.  Review AutoSupport settings on the controller pair.  Review the SMTP server status. NO.24 Click the Exhibit button at the right.When using ONTAP, the customer uses a mirror-SnapVault cascade, as shown in the exhibit. The Snapshot copies successfully transfer from the primary volume on storage system A to the SnapMirror destination on storage system B.However, not all SnapMirror Snapshot copies are being transferred from storage system B to the XDP destination on storage system C.In this scenario, which Snapshot copies will transfer successfully?  all manually initiated SnapMirror transfers  transfers initiated by a SnapMirror schedule  only Snapshot copies with the SnapMirror label called sm_created  any Snapshot copy created within the last 24 hours NO.25 Referring to the exhibit, the UNIX user “prof1” will be looked up in which source first?  nis  dns  ldap  files NO.26 A customer is trying to enable NVMe and wants to use the FC adapters in the controllers but cannot enable the protocol.Referring to the exhibit, what is causing the problem?  There are no FC adapters installed with the speed set to 32Gbps.  There are no FC adapters installed with a physical protocol set to NVMe.  There are no FC adapters installed with a max-speed of 32Gbps.  There are no FC adapters installed with a media type of NVMe. NO.27 After performing an upgrade in clustered Data ONTAP, you want to verify that the upgrade was successful.Which command would you use to verify this task?  system health controller sp upgrade show  version -node *  cluster ring show  cluster show NO.28 Referring to the exhibit.A storage administrator tells you that a company security mandate was applied to remove all CIFS share level permissions of everyone – full control. Now users are unable to access CIFS shares.The storage virtual machine (SVM) is named “SVM1” on clustered Data ONTAP 8.3.1. The storage administrator wants to know what can be done to restore full control access to users that are receiving “access denied” errors.The storage administrator has provided you with the vserver cifs share show command output of one of the CIFS shares with issues as shown in the exhibit.Which two steps must you perform to solve the problem? (Choose two.)  Execute the ::> vserver cifs share access-control delete -vserver SVM1 -share test9 – user-or-group domainA lnterngroup command from the controller.  Ensure that, in Active Directory, the desired users are members of the domainAcompanyusers group.  Execute the ::> vserver cifs share access-control delete -vserver SVM1 -share test9 – user-or-group Everyone command from the controller.  Ensure that, in Active Directory, the desired users are members of the domainA temps group. NO.29 Exhibit:Which two steps would you perform to correct the problem shown in the exhibit? (Choose two.)  Reseat the power supplies.  Reseat the shelf modules.  Replace the shelf chassis.  Perform a takeover and giveback. NO.30 You have an ONTAP 9.3 cluster and create a new SnapMirror relationship with a SnapMirror type of DP. You initialization the SnapMirror relationship and verify that incremental updates are operating as expected.However, you notice that the SnapMirror type is XDP instead of the specified DP.In this scenario, which statement is correct?  DP is not supported in ONTAP 9.3.  The SnapMirror policy type was set to MirrorAllSnapshots.  The destination cluster is running an older version of ONTAP.  All new relationships default to XDP. NO.31 Referring to the exhibit.Your customer’s MetroCluster controllers have generated AutoSupport notifications with a “DISK REDUNDANCY FAILED” message.Referring to the exhibit, which component is causing the problem?  the SAN switch site3_3  the SAN switch sitel_2  the inter-switch link (ISL) between site1 and site3  the ATTO bridges on site3 NO.32 A client is attempting to mount a UNIX security style volume using NFSv4. The client receives the“permission denied” message, but mounting NFSv3 works fine. You have confirmed both NFSv4 and NFSv3 are allowed in the export policy.Which statement describes this behavior?  There is no proper name-mapping rule for the user mounting.  Extended groups for AUTH_SYS are enabled.  The export policy applied to the volume has superuser set to none.  NFSv4 takes file permissions into account when mounting. NO.33 A customer asks what is the correct way to configure an ONTAP system for multi-tenancy. The customer wants to serve data and also protect data using SnapMirror from tenant A using network A and from tenant B using network B.In this scenario, which statement is correct?  The customer must use different VLANs for the two tenants.  This setup can only work if tenant A and tenant B use a shared network infrastructure.  The customer must set up two different IPspaces for the two tenants.  Each node can only communicate with tenant A or tenant B, but not with both at the same time. NO.34 Which database must be installed for deployments of OnCommand Unified Manager 6.x and OnCommand Performance Manager for Linux installations?  Oracle  MS SQL Server  Sybase  MySQL NO.35 Referring to the exhibit.A customer receives “CLUSTER NETWORK DEGRADED” AutoSupport messages from this clustered Data ONTAP system. The customer suspects that something occurred physically to the nodes after they had a data center maintenance move.The customer proceeds to follow the instructions in the Knowledge Base article regarding the “Error: CLUSTER NETWORK DEGRADED” message that results in the output shown In the exhibit.After analysis, the customer decides to replace the small form-factor pluggable (SFP) transceivers and the cables on the system.Which statistic supports the customer’s analysis?  CRC errors  Jumbo frames  BCast pkts  Multi/broadcast NO.36 You log in to a SnapMirror destination to review the system.Which scanner would you expect to see running?  active bitmap real management  container block reclamation  deswizzler  blocks used summary update NO.37 As part of your backup policy, you configured a local snapshot schedule on your production volume. You review the list of Snapshot copies and you do not see a snapshot from last night.What are two causes for this problem? (Choose two.)  The volume had 255 Snapshot copies.  A storage takeover happened.  Snapshot autodelete is enabled  The volume snapshot reserve was decreased. NO.38 Exhibit:A customer receives the AutoSupport message shown below.”(?] Sat Aug 23 13:00:27 PDT [hostname: env_rngr: callhome.c.fan.fru.fault:error] :Call home for CHASSIS FAN FRU FAILED: SysFan3 F2 (?] Sat Aug 23 13:00:32PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis fan Sysfan3 F2 is ok”The output of the sysconfig -a command is shown in the exhibit.In this scenario, what would you do to solve this problem?  Update Data ONTAP to 8.1.4 at the latest patch level.  Replace the fan.  Update the Service Processor firmware.  Disconnect the controller from the mains, wait two minutes, and re-connect it in the next maintenance window.  Loading … NetApp NS0-194 Exam Topics: SectionObjectivesData Protection-Identify data protection concepts-Demonstrate knowledge of data protection operationsNetApp Hardware-Identify the FRUs in a NetApp system-Demonstrate knowledge of the hardware replacement process-Describe storage hardware technology-Describe compute technology   Network Appliance Exam 2022 NS0-194 Dumps Updated Questions: https://www.validexam.com/NS0-194-latest-dumps.html --------------------------------------------------- Images: https://premium.validexam.com/wp-content/plugins/watu/loading.gif https://premium.validexam.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2022-10-23 15:52:04 Post date GMT: 2022-10-23 15:52:04 Post modified date: 2022-10-23 15:52:04 Post modified date GMT: 2022-10-23 15:52:04