This page was exported from Valid Premium Exam [ http://premium.validexam.com ] Export date:Fri Sep 20 0:43:45 2024 / +0000 GMT ___________________________________________________ Title: Get Real H12-425_V2.0 Quesions Pass Huawei Certification Exams Easily [Q182-Q202] --------------------------------------------------- Get Real H12-425_V2.0 Quesions Pass Huawei Certification Exams Easily H12-425_V2.0 Dumps are Available for Instant Access NEW QUESTION 182Huawei Technologies Co., Ltd. is GB50174-2008 standard is (), GB50174-2017 standard is ()  Participating units, auditing units  Participating units, participating units  audit unit, audit unit  Review unit, participating unit NEW QUESTION 183When UPS5000-E is installed in parallel, it is not necessary to connect the parallel cables of each UPS in the parallel system into a loop.  True  False NEW QUESTION 184The DC cable voltage drop needs to be controlled within ( ).  0.03  0.01  0.02  0.05 NEW QUESTION 185In the water-testing natural cooling scheme, the cooling tower can directly provide cooling water to the air conditioner to complete the cooling.  TRUE  FALSE NEW QUESTION 186In NETECO’s report management, which of the following types does periodic tasks have? (Multiple choice)  The Times  The Daily  Weekly report  Monthly report NEW QUESTION 187Which of the following technology or solution can reduce PUE? (Multiple choice)  Increase battery capacity  High Efficiency Modular UPS  Enclosed cold/hot aisles  Precise air supply NEW QUESTION 188When the distance between the outdoor unit and the sea is 0.5km~3.7km, you need to configure ( ) the outdoor unit. (Fill in the blank)  Class C NEW QUESTION 189( ) indicates the amount of electricity that a fully charged battery can release when it is discharged to the specified mid-branch voltage according to certain discharge conditions. The unit is expressed in AH or WH.  Actual capacity  Rated capacity  Maximum capacity  Minimum Capacity NEW QUESTION 190FusionModule2000 IT cabinet seismic rating?  8  9  7 NEW QUESTION 191When selecting to support only temperature detection and not to support hot-plug configuration, the switches in the slot must be fully configured.  True  False NEW QUESTION 192NETECO’s report functions are displayed in various forms, with a variety of visual presentations such as bar charts, pie charts, and curve charts.  TRUE  FALSE NEW QUESTION 193The operating temperature range of FusionModule800 is -40-45 degrees, and the operating temperature range of FusionModule500 is 0~45 degrees.  True  False NEW QUESTION 194If the UPS500E-400KVA is equipped with an IP21 configuration, the top outlet is not supported.  True  False NEW QUESTION 195In NETECO’s video menu, you can check the camera’s name, code, IP address, model, status and other detailed information.  True  False NEW QUESTION 196The AI/DI port on the access control actuator supports to connect the ().  IC card reader  Fingerprint Reader  Door open button  Electronic magnetic lock NEW QUESTION 197Unpredictable business, difficult expansion and investment are one of the challenges faced by traditional data center business development.  TRUE  FALSE NEW QUESTION 198Which of the following descriptions for the configuration of the PDU8000 modular precision power distribution cabinet is correct?  Modular precision power distribution cabinet supports single and dual input  Modular precision power distribution cabinet supports up to 4 output modules  The output module of the modular precision power distribution cabinet only supports 1P air switch  The input modules of the modular precision power distribution cabinet are MCCB and ATS. NEW QUESTION 199The reason why the fan does not turn when the NETCOL5000C device is turned on may be ().  The filter is dirty and blocked  The power supply module is faulty or abnormal  Failure of strong drainage system  Poor drainage of condensate NEW QUESTION 200In the UPS5000 configuration, different battery schemes can be obtained by adjusting the number of battery strings and the number of battery cells in a single group.  True  False NEW QUESTION 201When the single cell voltage in the battery pack reaches ( ), it means that the battery pack is already in a risky state. (Fill in the blank)  1.67V NEW QUESTION 202The user can modify the IP address of the ECC800 from the () menu on the ECC800WEB interface.  Micro module settings  Video IP settings  Time setting  Monitoring module IP  Loading … Get Instant Access REAL H12-425_V2.0 DUMP Pass Your Exam Easily: https://www.validexam.com/H12-425_V2.0-latest-dumps.html --------------------------------------------------- Images: https://premium.validexam.com/wp-content/plugins/watu/loading.gif https://premium.validexam.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2022-10-24 13:05:18 Post date GMT: 2022-10-24 13:05:18 Post modified date: 2022-10-24 13:05:18 Post modified date GMT: 2022-10-24 13:05:18