This page was exported from Valid Premium Exam [ http://premium.validexam.com ] Export date:Thu Nov 14 16:38:54 2024 / +0000 GMT ___________________________________________________ Title: Dumps of AD01 Cover all the requirements of the Real Exam [Q70-Q87] --------------------------------------------------- Dumps of AD01 Cover all the requirements of the Real Exam Correct Practice Tests of AD01 Dumps with Practice Exam What is the duration of the AD01 Exam Number of Questions: 60Cost: 60$Length of Examination: 60 minutesPassing Score: 70%Format: Multiple choices, multiple answers   Q70. Study the following page in a process:Calculation stages will write A, B or C to the Output value data item.What will be the outcome after the page has run?  Data Item Output Value contains “A”  Data Item Output Value contains “B”  Data Item Output Value contains “C”  An Internal Exception will be thrown Q71. A process contains only 4 stages Study the following process flow:The data Item Result’ is a number data item with an initial value of 2.The calculation stage is configured as follows:Following the execution of the Perform Calculation stage, which of the following is true?  The data item Result will contain 3  The data item Result will contain 5  The process will throw an exception  None of these statements are correct Q72. Study the following image showing pan: of the flow within a process:What problems do you see with the process flow? (select 2 responses)  There is a missing Recover stage on one of the routes through the flow.  There is a missing Resume stage on one of the routes through the flow.  The Retry Count is not being incremented for each retry.  If an exception is thrown in the Cancel Reservation page and is allowed to bubble up to be caught by the Recover stage, the Create Reservation action won’t be retried. ExplanationC,DQ73. Which of the following indicates a case in a Work Queue is waiting to be worked?         ExplanationQ74. The data item New Date is a date data item with no initial value.The calculation stage is configured as follows:What will happen when you execute the Create Date stage?  5 days will be added to today’s date and the result stored in the New Date data item.  1 month will be added to today’s date and the result stored in the New Date data item.  1 week will be added to today’s date and the result stored in the New Date data item.  The process will throw an exception as the New Date data item is null. Q75. Examine the flow below:An error has been encountered on Page1 and the exception has bubbled up to be recovered in the Recover1 stage. The ‘Yes’ path has been taken from the “Throw new Exception?” decision stage.Consider the Throw Exception stage properties below:How should the properties be configured for the Process to throw a new Business exception, i.e. a different exception to the one encountered in Page1?  Configure Exception Type() in the Exception Type field and ExceptionDetail() in the Exception Detail field. Leave the Preserve the type and detail of the current exception checkbox un-ticked.  Tick the Preserve the type and detail of the current exception checkbox. Leave the Exception Type and Exception Detail fields blank.  Leave the Exception Type field blank and type “Business Exception” in the Exception Detail field.  Type Business Exception in the Exception Type field and type a custom message in the Exception Detail field. Q76. Examine the following Blue Prism Process diagram:The ‘Retry Limit’ data item is configured as a number data item, and has an initial value of 3. The ‘Retry Count* data item is configured as a number data item, and has an initial value of 0. The ‘Count’ Calculation stage increases the value of the ‘Retry Count’ data item by 1. The ‘Retry? Decision stage contains logic to prevent more than 3 attempts What is wrong with the current configuration?  The Resume stage must also be within the exception block  Sub-pages should not have retry logic Exception handling should be in the Object layer rather than in the Process  The retry loop logic shown in the image is incorrect because it uses multiple action stages There should be a retry loop around every action  The retry loop logic does not include any actions after the resume stage to ensure the application is ready to try the ‘Search Screen – Perform Search’ Action again * Understanding the Diagram:* The diagram shows a retry loop where the process attempts to perform a search, read results, and handle exceptions by retrying up to 3 times.* ‘Retry Limit’ is set to 3, and ‘Retry Count’ starts at 0 and is incremented by 1 in each retry attempt.* Analyzing the Logic:* Option A: The Resume stage should resume the process outside the exception block, which is correct.* Option B: Exception handling in the process layer is valid; it does not have to be exclusively in the object layer.* Option C: Each action does not need an individual retry loop; the overall block retry is acceptable.* Option D: This option highlights a missing step. After handling an exception and before retrying, the application needs to be reset or ensured it is ready to retry the ‘Search Screen – Perform Search’ action.* Identifying the Issue:* The retry logic should include steps to ensure the application state is appropriate for another search attempt. This might include resetting fields, waiting for the application to be ready, or ensuring the previous error state is cleared.References:* Blue Prism Developer Documentation: Exception Handling and Retry Logic* Blue Prism Training Material on Process Flow and Exception HandlingQ77. Please refer to the exhibit.The Developer is automating an SAP Windows-based application within a Citrix environment. There is an issue with a duplicate match found when identifying and highlighting the Document No. field, due to the application window having two of the same labels and buttons.Which Spy Mode should the Developer use to identify the correct field using Surface Automation?  Win32  Browser  Application Navigator  Region In a Citrix environment, where traditional spying modes might not work effectively due to the nature of remote desktop applications, Surface Automation techniques are used. The Region mode allows you to define specific areas of the screen to interact with, making it suitable for environments where duplicate elements are present.* Region (Option D): This spy mode allows you to define a specific area on the screen and interact with elements within that region. This is particularly useful in Citrix environments where other spy modes might fail to differentiate between duplicate elements.The other options are less effective in this scenario:* Win32 (Option A): This mode is used for traditional Windows applications but might not work well in a Citrix environment.* Browser (Option B): This mode is designed for web-based applications and is not suitable for Windows applications in Citrix.* Application Navigator (Option C): This mode is not typically used for surface automation in Citrix environments.ReferencesConsult Blue Prism’s documentation on surface automation techniques and best practices for automating applications in Citrix environments.Q78. Consider the following process flow:What is the problem with this flow?  There is nothing wrong with this flow.  The exception handling in this flow can be removed because an Attach action in a navigate stage should always work if configured correctly  The Attach Block should be enlarged to also include the Waited Long Enough decision stage.  The flow contains a recover stage and a route from it without a resume stage. This will cause internal errors on future exceptions thrown in the same session.  The 0.5 second wait stage should be removed so that the retries can be performed at full speed. Q79. A Blue Prism Process works successfully when testing in the Process Studio but terminates in Control Room due to the exception stating screen elements were not found What should the Developer check first?  The correct Spy mode was used to identify elements  Application Modeller has a unique match for the screen element  Wait Stages have been used effectively  The Attach page is published in the Business Object * Spy Mode:* Blue Prism uses different spy modes (e.g., Win32, HTML, Region, etc.) to interact with various types of applications and elements within those applications.* Testing in Process Studio vs. Control Room:* A process may work in Process Studio because elements are correctly identified during testing, but it may fail in Control Room if the wrong spy mode was used, leading to elements not being found in the live environment.* First Check:* Verify that the correct spy mode was used to identify the screen elements. This ensures that the process can reliably locate and interact with these elements during runtime.References:* Blue Prism documentation on spy modes and element identification.Q80. Exhibit:What will be the outcome after the page has run?  Data Item Output Value contains A  Data Item Output Value contains B  Data Item Output Value contains C  An Internal Exception will be thrown Q81. Which of the following Stages can be found Process Studio but NOT Object studio?  Option A  Option B  Option C  Option D Q82. Please refer to the exhibits.All Data Items are of Text Data TypeWhat is the output once all stages are executed?  Recent Activity (or John – Orders: AR34675 Refunds: CAB30981  Recent Activity (or 4320 – Orders: REF4399 Refunds: USD18.99  Recent Activity for 4320 – Orders: AR34675 Refunds: CAB30981  Recent Activity for John – Orders: REF4399 Refunds: USD18.99 * Data Items:* Data1: “AR34675 is your order no for item REF4399”* Data2: “USD18.99 refunded for Item CAB30981”* Data3: “Acc# – 4320; Name – John Doe”* Calculation Expression:“Recent Activity for “& [Data3]& ” -” &” Orders: ” & [Data1] &” Refunds: ” & [Data2]* Breaking Down the Expression:* Recent Activity for “& [Data3]& ” -“:* Concatenates “Recent Activity for ” with Data3 and ” -“.* Data3 is “Acc# – 4320; Name – John Doe”.* Result: “Recent Activity for Acc# – 4320; Name – John Doe -“* ” Orders: ” & [Data1]:* Adds ” Orders: ” to Data1.* Data1 is “AR34675 is your order no for item REF4399”.* Result: ” Orders: AR34675 is your order no for item REF4399″.* ” Refunds: ” & [Data2]:* Adds ” Refunds: ” to Data2.* Data2 is “USD18.99 refunded for Item CAB30981”.* Result: ” Refunds: USD18.99 refunded for Item CAB30981″.* Combining the Results:* “Recent Activity for Acc# – 4320; Name – John Doe – Orders: AR34675 is your order no for item REF4399 Refunds: USD18.99 refunded for Item CAB30981”* Final Output:* Remove extraneous details to match the correct format:* “Recent Activity for 4320 – Orders: AR34675 Refunds: CAB30981”References:* Blue Prism documentation on data item manipulation and string concatenation.Q83. Consider the following flow within an Object Studio action:The developer of this flow found that writing some credentials to the target application sometimes failed with an exception even though the element exists on the screen. He found that simply catching the exception, waiting for 2 seconds and then retrying fixed the problem.What problems do you see within the flow? (select 2 responses)  A block has not been placed around the Write stage and the Recover stage, meaning the credentials action could be unnecessarily retried if another stage further into this action throws an exception.  There is a potential for an infinite loop if the ‘Credentials’ stage keeps throwing an exception for some unforeseen reason.  The credentials stage is a read stage not a write stage.  There is not a Resume stage following the timeout of the Wait stage Q84. The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New Order screen is in focus?A:B:C:D:  Option A  Option B  Option C  Option D Q85. A Filename is the path and file name to which the Excel file should be saved Which of the following Expressions would return a valid Filename?  RepJacedFile Name],” xlsx” “”)&” xlsx”  [Root Folder)&[Flle Name]&’xlsx”  LoadTextFiie((Root FokJer]&’V&” xlsx”  [Root Folder]&’V&[File Name] In Blue Prism, to construct a valid file path from a root folder and a file name, you need to concatenate these two strings with the appropriate directory separator (backslash in Windows). The correct expression combines the root folder, a backslash, and the file name to form a complete path.* [Root Folder]&”&[File Name] (Option D): This expression correctly concatenates the root folder and the file name with a backslash in between, forming a valid path.For example, if [Root Folder] is “C:UsersExam TakerDownloads” and [File Name] is “File_to_Save.xlsx”, the result would be “C:UsersExam TakerDownloadsFile_to_Save.xlsx”.The other options are incorrect:* ReplacedFile Name],” xlsx” “”)&” xlsx” (Option A): This contains syntax errors and incorrect handling of file extensions.* [Root Folder)&[File Name]&’xlsx” (Option B): This incorrectly places the file extension as a separate string, and there is a syntax issue with the parenthesis.* LoadTextFile([Root Folder]&”&” xisx” (Option C): This uses an incorrect function (LoadTextFile) and has a typo in the extension.ReferencesRefer to Blue Prism’s documentation on string manipulation and expression building to understand how to correctly concatenate strings to form file paths.Q86. After launching the order processing application, the following login screen is displayed to the user, requesting their login details:The following Launch Action has been created in Blue Prism:According to Blue Prism best practice, what should be configured between the Launch and End stages?  A Wait Stage to check for an element on the Login screen  A Navigate stage to Attach to the application  A Write stage to enter the Staff Number and Password  A Read Stage to read an element from the Login screen * Analysis of the Launch Action:* The action involves launching an order processing application, which brings up a login screen requesting the user’s login details.* The flow in the question shows a ‘Launch’ stage and an ‘End’ stage with no intermediate stages.* Blue Prism Best Practices:* According to Blue Prism best practices, after launching an application, it is essential to verify that the application has loaded successfully and is ready for further interaction.* This verification is typically done using a wait stage to check for the presence of specific elements that confirm the application is ready, in this case, elements on the login screen.* Reasoning for the Wait Stage:* The Wait stage ensures that the login screen has fully loaded and the elements are available for interaction.* This prevents the automation process from proceeding to the next steps too quickly, which could lead to errors if the elements are not yet ready.* Implementation:* Insert a Wait stage immediately after the Launch stage.* Configure the Wait stage to check for a specific element on the login screen, such as the ‘Staff Number’ field or the ‘Sign In’ button.* Only proceed to the next stages (entering login details, etc.) once the Wait stage confirms the presence of the required elements.References:* Blue Prism Developer Documentation: Best Practices for Wait Stages* Blue Prism Training Material on Login Automation ProceduresQ87. Study at the following diagram which is an extract from a sub-page of a process being tested in Process Studio:There are no breakpoints in the “Access Customer Account” subpage however there is an error.What will happen if you choose to step out (SHIFT+ F11) when debugging the process?  The process will work all stages in the “Access Customer Account page until the error is thrown and then focus would move to the breakpoint at “Get Customer Details” stage.  The process will work all stages in the ‘Access Customer Account1 page until the error is thrown and then focus would move to the “Recover 1 stage  The process will work all stages in the “Access Customer Account’ page until the error is thrown and then focus would move to the stage containing the error on the “Access Customer Account” page,  The process will work all stages in the “Access Customer Account” page until the error is thrown and then focus would move to the “Exception 1 stage.  Loading … The AD01 exam covers a wide range of topics related to Blue Prism's RPA technology. These topics include but are not limited to: Blue Prism architecture, process flow creation, debugging, exception handling, and data manipulation. AD01 exam is designed to test the candidate's understanding of Blue Prism's RPA technology and how to apply it to real-world scenarios. Candidates who pass the exam will be able to demonstrate their ability to design, build and implement Blue Prism RPA solutions.   Sample Questions of AD01 Dumps With 100% Exam Passing Guarantee: https://www.validexam.com/AD01-latest-dumps.html --------------------------------------------------- Images: https://premium.validexam.com/wp-content/plugins/watu/loading.gif https://premium.validexam.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2024-09-11 13:01:46 Post date GMT: 2024-09-11 13:01:46 Post modified date: 2024-09-11 13:01:46 Post modified date GMT: 2024-09-11 13:01:46